Cat. 6 網路跳線捲線
Cat. 6 UTP Coiled Patch Cord, coiled-shape cable, 4 twisted pairs covered with thick jacket, coiled patch cord can be easily fitted in the workplace and cabinet with no tangle.
Features
- • 出廠 100% 通過 Fluke 通道(Channel)測試驗證。
- • 提供多種外被顏色選擇。
- • 支援 Gigabit 乙太網路(Gigabit Ethernet)、100BASE-TX 及 10BASE-T。
Standard Compliance
RoHS COMPLIANCE FOR THE REQUIREMENT OF EUROPEAN UNION ISSUED DIRECTIVE 2011/65/EU
Construction
| CAT. 6 COILED PATCH CABLE | |
CONDUCTOR | MATERIAL/SIZE | BARE COPPER, 28AWG |
DIAMETER | 7/0.12MM +/-0.003MM | |
INSULATION | MATERIAL | HDPE(CMI-75E) |
THICKNESS | MIN. AVERAGE THICKNESS: 0.13MM MIN.THICKNESS: 0.10MM | |
COLOR CODE | PAIR 1: BLUE & WHITE/BLUE PAIR 3: GREEN & WHITE/GREEN PAIR 2: ORANGE & WHITE/ORANGE PAIR 4: BROWN & WHITE/BROWN | |
DIAMETER | 0.57 +/-0.03MM | |
TENSILE STRENGTH | 16.5 MPA / 2400 PSI | |
ULTIMATE ELONGATION | ≥300% | |
JACKET | MATERIAL | ELASTOMER PVC |
THICKNESS | MIN. AVERAGE THICKNESS: 1.35MM MIN.THICKNESS: 1.0MM | |
OVERALL DIAMETER | 5.1MM +/-0.3MM | |
MINIMUM BENDING RADIUS | ≥ 8 TIMES OF OVERALL DIAMETER | |
MAXIMUM PULLING TENSION | MAX. 85N | |
TENSILE STRENGTH | 13.8MPA / 2000 | |
ULTIMATE ELONGATION | ≥100% | |
Electric Requirement (Cable Length/100m)
| CAT. 6 UTP STRANDED |
CHARACTERISTIC IMPEDANCE (Zo) | 85 ~ 115Ω (1 ~ 250 MHz) |
DC. RESISTANCE CAPACITANCE UNBALANCE | 5% |
PAIR-TO-GROUND CAPACITANCE UNBALANCE | 330 pF / 100M Max |
CONDUCTOR RESISTANCE | 7.32Ω / 100M 20°C Max. |
MUTUAL CAPACITANCE | 5600 pF / 100M MAX. |
SPARK TEST | 2.5KV |
NOMINAL VELOCITY OF PROPAGATION (N.V.P.) | 69% |
Environmental Condition & Usage
| TEMPERATURE RANGE | SHIPPING & STORAGE | -20°C to 75°C |
|---|---|---|
| INSTALLATION | 0°C to 50°C | |
| OPERATION | -10°C to 60°C | |
| MINIMUM BENDING RADIUS | ≥ 4 TIMES OF OVERALL DIAMETER | |
| MAXIMUM PULLING TENSION | ≤ 110 N | |
Section Plans

Transmission Requirements
FREQUENCY | MAX. ATTENUATION | MIN, Pr-Pr NEXT | MIN. PSNEXT | MIN. RETURN LOSS |
1 | 2.4 | 74.3 | 72.3 | 20.0 |
4 | 4.5 | 65.3 | 63.3 | 23.0 |
10 | 7.1 | 59.3 | 57.3 | 25.0 |
16 | 10.2 | 54.8 | 52.8 | 25.0 |
20 | 12.8 | 51.9 | 49.9 | 23.3 |
31.25 | 18.5 | 47.4 | 45.4 | 20.7 |
62.5 | 23.8 | 44.3 | 42.3 | 19.0 |
100 | 34.8 | 39.8 | 37.8 | 16.4 |
250 | 39.4 | 38.3 | 36.3 | 15.6 |
Applications
- • 移動式工程檢測與維護:現場弱電工程師隨身量測儀器、Fluke 測試儀及筆記型電腦除錯跳接,線材好收納不紊亂。
- • 醫療與手推推車設備(Medical Carts):移動式護理車、超音波推車及醫療終端與牆面資訊座的彈性連線,防止推移時線材扯斷。
- • 工業移動機台與昇降工作站:電動升降辦公桌、各類高低可調工作平台及產線移動作業終端之連線。
- • 收銀 POS 系統與商業櫃檯:零售店面、銀行臨櫃與出納窗口等空間受限且設備需小範圍挪動之結帳連網。
- • 伺服器機櫃臨時除錯(Console Port):機房網管人員連接筆電至 Switch / Router 進行設定維護時的俐落跳線方案。
- Related Products
Category 6 F/UTP 網路線
Hyper-Data 2000 Cat.6 F/UTP 網路線在四對對絞線外層包覆整體鋁箔麥拉帶(Aluminum-Polyester Tape),並配置單芯鍍錫銅接地引流線(Drain Wire)。此結構能有效阻絕來自天花板燈具、管道間及平行 AC 電源線所產生的射頻干擾(RFI),確保企業辦公環境中的千兆(Gigabit)乙太網路通道在 250MHz 頻寬下穩定運作。
Category 6 SF/UTP 網路線
這款 Cat.6 SF/UTP 網路線結合總鋁箔包覆與外層鍍錫銅網編織,兼具優異的抗電磁干擾(EMI)能力與高機械耐壓強度。在 250MHz 頻寬與千兆傳輸下,能有效保護數據訊號免受馬達突波、開關暫態脈衝與實體磨損的破壞,是工廠中控配電盤、自動化機台與產線設備箱內部配線極具信賴感的選擇。
28AWG 極細網路跳線
極細 28AWG Cat.6 與 Cat.6A 網路跳線搭配窄版防卡護套,相較於傳統 23AWG、24AWG 跳線更加輕巧細緻、柔軟好彎折。超細徑設計能徹底解決線槽擁擠塞滿的問題,大幅改善機櫃內部的通風散熱對流,是高密度伺服器機房與資料中心提升維護效率的理想整線方案。
Cat. 6 非屏蔽網路跳線
Cat.6 U/UTP 高速非屏蔽 RJ45 網路跳線專為 1000BASE-T、100BASE-TX 與 100BASE-T 等乙太網路應用打造。支援高達 250MHz 頻寬,具備優異的抗近端串音與低訊號衰減特性,插拔耐用且訊號傳輸穩定,是各類工作站終端、網路交換器及配線架跳接兼具施工效率與高相容性的標準首選。
- Files Download